Bug #5133

Incorrect work of USALS

Added by Shprot Shprot 25 days ago. Updated 10 days ago.

Status:NewStart date:2018-06-21
Priority:NormalDue date:
Assignee:-% Done:

0%

Category:-
Target version:-
Found in version:HTS Tvheadend 4.3-1273~g610c6fa Affected Versions:

Description

There is a TBS5580 and a Moteck SG-2500 motor. Periodically, the motor can start moving only after I start the channel several times in a row. After a long downtime (more than 8-10 hours) the same problems.

Screenshot_2.png (9.37 KB) Shprot Shprot, 2018-06-21 12:34

Screenshot_1.png (18.1 KB) Shprot Shprot, 2018-06-21 12:34

Screenshot_4.png (4.43 KB) Shprot Shprot, 2018-06-21 12:34

Screenshot_5.png (6.86 KB) Shprot Shprot, 2018-06-21 12:34

Screenshot_6.png (12.6 KB) Shprot Shprot, 2018-06-21 12:34

tvheadend.log (5.49 KB) Shprot Shprot, 2018-06-22 08:11

History

#1 Updated by Jaroslav Kysela 25 days ago

--trace linuxdvb,diseqc : https://tvheadend.org/projects/tvheadend/wiki/Traces

Describe the log (assign time to the action or what action do you expect).
Also, describe your equipment (topology). I would prefer this than to pick the info from the config images.

#2 Updated by Shprot Shprot 24 days ago

TBS5580 -> Diseqc 1.0 4 port -> Motor
First I started the channel with a 53E but the motor on it not turned, after launched channels 60E and there he began to move.

#3 Updated by Jaroslav Kysela 24 days ago

Try to increase DiseqC repeats for the rotor config. If you look to the log, the tvh correctly sends the USALS diseqc commands and waits for the rotor move.

#4 Updated by Shprot Shprot 24 days ago

I tried pointing out 1 and 2 but it didn't help.

#5 Updated by Digi Hoe 18 days ago

Do you have the problem if you use port1 for the motor on your switch?

Best regards!

#6 Updated by Shprot Shprot 10 days ago

Unfortunately, did not help